5.4.3 Sealing
1 Piston sealing
A sealing wire feeds through the head of a seal screw fitted in each piston end cover. This seal
wire also diverts upwards between two of the end covers to feed through a seal screw securing
the top housing to the meter body.
The seal wire is drawn taught and a seal fixed for stamp access above the calibration quadrant.
2 Pulser sealing
A sealing wire feed through holes in the bottom right hand corner of the pulser casting and
meter housing, then travels diagonally across the front of the pulser to pass through either a
hole in the meter mounting plate or the head of the front meter mounting screw.
The seal wire is drawn taught and a seal fixed for stamp access in front of the pulser.
3 Calibration sealing
A seal wire passes through holes in the calibration locking screw drawn taught and a seal fixed.
4 Meter sealing
The meter is sealed into the dispenser by passing a seal wire through the heads of two of the
meter mounting screws.
The seal wire is drawn taught and a seal fixed for stamp access on the top of the hydraulic
stack.
5.4.3.1 Alternative Sealing of MA26 meter and MP-T1 pulser
The following numbers refer to Figure 31:-
1 Piston sealing
Sealing wire feeds through the head of a sealing screw fitted in each piston end cover. This
seal wire also diverts upwards between two of the end covers to feed through a seal screw
securing the top housing to the meter body. The seal wire is drawn taught and a seal fixed for
stamp access above the calibration quadrant.
2 Pulser sealing
A sealing wire feeds through holes in the bottom right hand corner of the pulser casting and
meter housing, then diagonally across the front of the pulser to pass through a hole in the head
of the front meter mounting screw. The seal wire is drawn taught and a seal fixed for stamp
access in front of the pulser.
3 Calibration sealing
A seal wire passes through holes in the calibration locking screw drawn taught and a seal fixed.