Quantum AML/2 Guía de usuario Página 72: Start “MANUAL”

Operating The AML/2 System
Page 5 - 32 Operator Guide 1097 DOC B00 001
5.9 Start “MANUAL”
In this operating mode the drive amplifiers of the robots are voltageless.
This operating mode is intended exclusively for:
• input and output of media
• manual operation of drives
• automatic movement of Quadro towers.
WARNING!
Movements of system components inside the archive can cause severe injury.
Before starting the system ensure that nobody is inside the archive.
The AML/2 system must be operated exclusively by trained personnel that is regi-
stered in the system logbook.
a) Set the operating mode selector switch to “MANUAL”, remove the key and
keep it in a place unaccessible for unauthorized persons.
b) Switch the main switch on.
<CONTROL OFF> lights up yellow.
c) Press <SYSTEM ON>.
<SYSTEM ON> lights up green: EMERGENCY STOP circuit is activated.
d) Press <CONTROL ON>.
<CONTROL OFF> remains on, <CONTROL ON> lights up green.
The drive amplifiers for the Quadro towers are switched on.
The Quadro towers can be addressed via the AMU (Manual Operation) opera-
ting panel.
5.10 Changing the Operating Mode
a) Select 6KXW GRZQ$%%$
b) Press <CONTROL OFF>.
<CONTROL ON> switches off, <CONTROL OFF> lights up yellow.
c) Change the operating mode.
d) Press <CONTROL ON>.
e) Restart AMU: enter „startup“ in an OS/2 window.
!
Archivo PDF · ·
Preguntas sobre Quantum AML/2
Todavía no hay preguntas sobre este manual. Haga la primera.
Productos y manuales relacionados para Sistemas operativos Quantum AML/2
- Sistemas operativos Quantum DAT 40 Drive Guía de usuario
(19 páginas) - Sistemas operativos Quantum AML/2 aviso
(24 páginas)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98