Quantum AML/2 Guía de usuario

Busca en línea o descarga Guía de usuario para Sistemas operativos Quantum AML/2. Quantum AML/2 User's Guide Manual de usuario

/ 66
Tabla de contenidos
The AML/2 Library

Planning Guide

Archivo PDF · ·

Imprimir

Imprimir documento

Compartiendo

Índice de contenidos

Página 1 - Planning Guide

The AML/2 Library Planning Guide

Página 2 - Copyright Notice (Europe)

ADIC CORPORATE • 11431 WILLOWS ROAD, NE • REDMOND, WASHINGTON, USA • 1-800-336-1233 ADIC • 8560 UPLAND DRIVE• ENGLEWOOD, COLORADO, USA •…

Página 3 - Contents

Contents Introduction Intended Audience 1-1 Organization 1-1 Associated Documents 1-2 Assistance 1-2 Description System Function 2-2 AML/2 Hardware…

Página 4

iv Contents 600135-E Open System Support 2-14 Distributed AML Server (DAS) Software 2-14 Specification Physical Specifications 3-2 Dimensions 3-2…

Página 5 - Actual Scenario

Contents v 07 Nov 2003 Communication Software 4-5 Special Engineering Request 4-5 Customer System Layout 4-5 Survey Customer and Installation Site…

Página 6

vi Contents

Página 7

Figures Figure 2-1 Basic AML/2 Configuration: One Quadro Tower and One Robot 2-1 Figure 2-2 Robot Gripper with Barcode Scanner 2-4 Figure 2-3 Track…

Página 8

viii Figures

Página 9

Tables ix Table 3-1 AML/2 Component Physical Dimensions and Loading 3-2 Table 3-2 AML/2 Component Electrical Specifications 3-3 Table 3-3 AML/2…

Página 10

xTables

Página 11 - Organization

Intended Audience 1-1 07 Nov 2003 1- Introduction This manual contains information that outlines the AML/2 library 1 . The topics discussed in this…

Página 12 - Assistance

2 Introduction 600135-E Associated Documents 600043 AML/2 Operator Guide 600141 AML/2 Maintenance Guide 600300 AML Hardware Configuration Information…

Página 13

The ADIC Automated Media Library/2 (AML/2) is a fully automated, robotic media library that offers an enterprise solution to data management and…

Página 14 - System Function

System Function Major system components include the following items: • Host •AMU • Controllers The basic operational philosophy of the AML/2 centers…

Página 15 - AMU Basic Functions

AMU Hardware Components AMU hardware consists of the following components: • computer with a color monitor, a mouse, and a keyboard • Token Ring…

Página 16

Robot Media movements are performed by a robot equipped with a mixed-media gripper and a laser barcode scanner. See Figure 2-2. Typical movements…

Página 17 - Storage Segment

Track Section The robot travels on track sections that measure 3’ 8” in length. A minimum of three track sections are required for each storage system…

Página 18 - Quadro Tower

Quadro Tower The Quadro Tower provides the maximum media storage density with the minimum floor space required for a library system. The AML/2 can be…

Página 19

Figure 2-5 Single AML/2 Quadro Tower (Top View) The average time to retrieve and mount a cassette is between 2.5 and 6 seconds. The Quadro Tower’s…

Página 20 - AMU Control Cabinet

AMU Control Cabinet The AMU Control Cabinet houses the electronics that link the host computer to the rest of the system. See Figure 2-6. The control…

Página 21 - Robot Control Cabinet

Robot Control Cabinet The Robot Control Cabinet houses the electronics which control the robotics of the AML/2. The AMU sends commands to this unit…

Página 22 - Tower Control Cabinet

Tower Control Cabinet The Tower Control Cabinet houses the electronics which control the circular movement of the Quadro Tower. Commands are received…

Página 23 - Universal Drive Cabinet

Universal Drive Cabinet The Universal Cabinet contains drive units and optional drive controllers. See Figure 2-9. Figure 2-9 Universal Drive Cabinet

Página 24 - Manual Insert/Eject Unit

Manual Insert/Eject Unit Media are inserted into the AML/2 system and ejected through the Insert/Eject Unit. The operator loads media from the outside…

Página 25 - AML/2 Software Components

AML/2 Software Components 2-13 07 Nov 2003 AML/2 Software Components ADIC software controls all functions in the AML/2, making automated data backup…

Página 26 - Open System Support

Open System Support Distributed AML Server (DAS) Software DAS software operates with both client and server components. The server software modules…

Página 27

This section contains information about the following aspects of the AML/2 library: • Physical Specifications •Dimensions • Inside the crate •Outside…

Página 28 - Physical Specifications

Physical Specifications Dimensions Table 3-1 provides information for the physical size, weight and loading of ALM/2 library components. Table 3-1…

Página 29 - Electrical Specifications

Electrical Specifications 3-3 07 Nov 2003 Electrical Specifications Table 3-2 lists the basic electrical specifications for the components of the…

Página 30

Tower Control Cabinet 208 VAC 1 phase 0.4 1.9 1219 AMU Control Cabinet Manual I/E Facility 208 VAC 1 phase 0.01 0.05 30 AMU Control Cabinet Robot 0.8…

Mostrar las 66 páginas
Página 31 - Clean Room Specification

Performance Specifications 3-5 07 Nov 2003 Performance Specifications Table 3-3 lists performance specifications for the AML/2 library. Actions refer…

Página 32 - Vibration

Vibration Significant vibration (high amplitude) occurring while drives are writing will result in drives having to rewrite data, thereby reducing…

Página 33 - Regulatory Specifications

Regulatory Specifications 3-7 07 Nov 2003 Regulatory Specifications Table 3-5 lists the key safety and electromagnetic regulatory specifications for…

Página 34 - Media Quantity Specifications

Media Quantity Specifications Table 3-6 lists the number of cassette media by type that can be stored in Quadro Towers and Linear Racks for the AML/2…

Página 35

Media Quantity Specifications 3-9 07 Nov 2003 Optical Disk Reflection 80 3 / 4 3456 95 5 / 8 4224 110 3 / 4 4992 DTF small 80 3 / 4 2048 95 5 / 8 2560…

Página 36 - Barcode Requirements

Floor Electrical Requirements Flooring must meet specifications for being dust-free, and physically, chemically, and acoustically certified. In…

Página 37

Standard Drives Supported by ADIC 3-11 07 Nov 2003 Standard Drives Supported by ADIC Several different drives types can be used with the AML/2 Library…

Página 38

ADIC (OEM) DLT 7001 * SCSI-2 (DE), (F/ W) 212 6 ADIC (OEM) DLT 7001S * Low Profile SCSI-2 (DE), (F/ W) 224 4 - 6 ADIC (OEM) DLT 8001S * Low Profile…

Página 39

Standard Drives Supported by ADIC 3-13 07 Nov 2003 SONY BVW-75P Video 1 4 4 Media: 8mm ADIC (IBM OEM) LT01 LT02 LT03 SCSI SCSI SCSI 2 2 2 24 24 24 4…

Página 40

* The following drives are composed of three different types of installation units. • 1 mounting kit (2 drives/kit) = 1 level= 2 drives • 1 mounting…

Página 41 - Storage Types

System Heights 4-1 07 Nov 2003 4- Configuration The purpose of this chapter is to assist prospective customers and new owners in planning for an AML/2…

Página 42 - Media Types

Media Types Enter the quantity of the desired media type (maximum 5). 3480/3490E/3590/9840/9940 OD512 OD-R D2S D2M VHS DLT/SDLT DvcPro small/AIT…

Página 43 - Insert/Eject Types

Drive Types 4-3 07 Nov 2003 Drive Types Enter the desired quantity of drive types (maximum 5), and state if the drives require rack mounting.…

Página 44 - Universal Drive Cabinets

Insert/Eject Handling Boxes Enter the quantity of the media type handling racks. Refer to Media Types on page 4-2 for the chosen media types. Media…

Página 45 - Customer System Layout

Host Connection 4-5 07 Nov 2003 Host Connection Check ( ) the requested type of connection. Communication Software Check ( ) if Remote Access…

Página 46

Figure 4-1 Customer AML/2 Configuration Layout

Página 47 - Scale: 1/4" = 1’

Customer System Layout 4-7 07 Nov 2003 Figure 4-2 Example AML/2 Configuration Quadro Tower Robot Scale: 1/4" = 1’

Página 48 - Figure 4-3 Cutout Examples

Figure 4-3 Cutout Examples Scale: 1/4" = 1’

Página 49 - Information

Customer and Installation Site Information 5-1 07 Nov 2003 5- Survey Use this section to record relevant information about the delivery site and…

Página 50

Physical Environment Specifications Record any additional information in Additional Comments on page 5-10. Installation Contact: #1 Installation…

Página 51

Physical Environment Specifications 5-3 07 Nov 2003 Floor Type: Floor Load Capacity: Fire Protection: Other Issues to Consider::

Página 52 - Customer Room Layout

Customer Room Layout Sketch the approximate measurements of the AML/2 library room and any obstructions. Establish your own grid scale. Figure 5-1…

Página 53 - Site Preparation

Site Preparation 5-5 07 Nov 2003 Site Preparation The following customer supplied circuits are necessary for the proper installation and operation of…

Página 54 - Customer Building Layout

Customer Building Layout Sketch the building layout that indicates the route from the loading dock to equipment final destination. Indicate…

Página 55 - Access Conditions

Site Preparation 5-7 07 Nov 2003 Access Conditions Access to AML/2 library room (elevator, stairs, door widths, etc.): Dimensions and Location of…

Página 56 - Location for Uncrating:

Where Can Trailer Be Left for Staging? Availability of Material Handling Equipment: Location for Uncrating: Preferred Time of Day for Unloading and…

Página 57 - Other Considerations:

Site Preparation 5-9 07 Nov 2003 Procedure for Obtaining Building Passes: Procedure for Scheduling Use of Elevator, Loading Dock, etc.: Waste Disposal…

Página 58 - Additional Comments

Additional Comments Record any additional information that pertains to the installation. Note the page number of topics in this document which need…

Página 59 - Single Robot Example

Single Robot Example A-1 07 Nov 2003 A- Configuration Examples The ADIC Automated Media Library/2 (AML/2) is a fully automated, robotic media library…

Página 60

A-2 Configuration Examples 600135-E S1-3 72X78X23 Top Plate, Struts, Columns 1 S1-4 98X51X61 Bins 1 S1-5 94X25X47 QT Doors, Enclosure, Profiles, Step…

Página 61

Single Robot Example A-3 07 Nov 2003 Table A-2 AML/2 Two Robots with One Tower - 2.43M S1-30 42X25X23 DST-312 Drives 1 T1-1 72X36X72 Tool Box 1 Crate…

Página 62

A-4 Configuration Examples 600135-E Table A-3 AML/2 Two Robots with One Tower - 2.8 M S1-23 42X25X23 DST-312 Drives 1 S1-24 42X25X23 DST-312 Drives 1…

Página 63

Single Robot Example A-5 07 Nov 2003 S1-17 45X35X86 Drive Cabinet 1 S1-18 45X35X86 Drive Cabinet 1 S1-19 93X31X49 Walkways, PC & Monitor 1 S1-20…

Página 64 - A-6 Configuration Examples

A-6 Configuration Examples

Página 65 - Vibration Scenario

Vibration Scenario B-1 07 Nov 2003 B- Actual Scenario The following Scenario was based on an actual event. The user was preparing for major…

Página 66 - Dust Scenario

B-2 Actual Scenario 600135-E ADIC recommends that the movement and placement of the steel be scheduled to coincide with the time that the robots and…

Más documentos para Sistemas operativos Quantum AML/2

Preguntas sobre Quantum AML/2

Todavía no hay preguntas sobre este manual. Haga la primera.

Hacer una pregunta

Respondemos con el manual e indicamos la página. La pregunta se publica en el sitio después de revisarla.

Todas las preguntas y respuestas ›

Productos y manuales relacionados para Sistemas operativos Quantum AML/2