Benchmark DLT1 Drives & Media
Troubleshooting DLT1 Tape Drives
Chapter 33-16
Media Compatibility Issues
Table 3-5 lists potential error messages and what may cause them.
NOTE If you experience any failures with reused Quantum DLT formatted
(degaussed) cartridges, the degaussing may not have been sufficient to
fully erase the data. If this happens, use another piece of media
(preferably a new, unformatted DLT Type IV cartridge) before suspecting
other system components.
Table 3-5 Media Compatibility Issues
Message Cause
Media format invalid for
drive type.
An attempt was made to load
incompatible media into a DLT1 tape
drive. Ensure your media and format is
compatible with a DLT1 tape drive. (See
“Using DLT1 Tape Cartridges” on page
3-5.)
Media is write protected -
restore from tape
successful.
Media with the DLT 4000 format was
loaded into a DLT1 tape drive. The data
is readable but the media must be bulk
erased before a DLT1 tape drive can
write to this tape. (See “Bulk Erasing
Tape Cartridges” on page 3-6.)
Media is write protected -
restore from tape NOT
successful.
An attempt was made to load media
with a DLT 7000 or 8000 format into a
DLT1 tape drive. The format is
incompatible and the data cannot be
read. The media must be degaussed
before a DLT1 tape drive can write to
this tape. (See “Bulk Erasing Tape
Cartridges” on page 3-6.)
Comentarios a estos manuales