Chapter 3: System Specifications
Electrical Specifications
64 Scalar i6000 Planning Guide
Notes:
• Drive values are writing uncompressed data (worst case)
• Max 18 drives in a Control Module
• Dual robot feature only available with Gen 2 Robot
• Dual robot values are for single MCB control, not redundant MCB
• Robot numbers are operating
• Base Module value does not include a robot or a drive
Table 6 SEM and DREM Power
Consumption
Subsystem AMP @ 110 V AMP @ 220 V
DC AMP
@ 48 V
kW BTU/hr
Base Module 0 0 0 0 0
Base Module - Extra Drives 0 0 N/A 0 0
2nd PS2508 Power Supply 0.73 0.36 1.67 0.080 272.8
2nd PS2571 Power Supply
a
0.75 0.37 N/A 0.080 272.8
IBM LTO-6 Drive (each) 0.3 0.15 0.71 0.034 115.9
IBM LTO-5 Drive (each) 0.4 0.2 1.0 0.045 153.5
IBM LTO-4 Drive (each) 0.35 0.18 0.8 0.038 129.6
HP LTO-6 Drive (each) 0.25 0.13 0.58 0.028 95.5
HP LTO-5 Drive (each) 0.25 0.13 0.58 0.028 95.5
HP LTO-4 Drive (each) 0.3 0.15 0.73 0.035 119.4
I/O Management Unit 0.5 0.25 1.5 0.052 177.3
FC I/O Blade (each) 1.0 0.5 2.0 0.110 375
Ethernet Expansion Blade (each) 0.1 0.05 0.2 0.010 34.1
a - used for Series 3 modules only
Comentarios a estos manuales