Drive Cleaning Tasks
106 SL500 User’s Guide July 2008 Revision: KA 96116
Configure Drive Auto Clean
Use this procedure to enable or disable the drive auto clean feature. If the library is
partitioned, auto clean can be enabled or disabled for individual partitions.
Note – This procedure applies only to drives that are not managed by HSC or ACSLS.
See the HSC and ACSLS documentation for details about how they manage automatic
cleaning operations.
1. Select Tools > System Detail, and select the library folder on the device tree.
2. Click Auto Clean and then Configure.
The Configure Auto Clean screen appears.
3. Set the Auto Clean field to Enabled.
4. In the Threshold Configuration section, specify the warning thresholds for each
cartridge type.
5. Click Apply.