Quantum Scalar 1000 Guía de usuario Pagina 110

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 122
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 109
102 Troubleshooting the SAN
4 When you are finished viewing the data, select OK.
5 Environmental data ranges may vary from appliance type to appliance type.
Using Health Check
Health Check allows you to determine periodically the operational state of SNC connections to the
interfaces it controls. When the Health Check is disabled, the SNC performs no periodic checks beyond
monitoring environmental status lines, which indicate power supply and temperature conditions. The Health
Check function posts SNMP traps when required to convey status information to the user interface.
Performing Health Check
The Perform Health Check command requests an immediate health check at the current level specified.
This check is performed regardless of the Health Check Interval setting.
1 Right-click an appliance in the navigation panel or the graphical panel.
2 Select the Health Check menu, then select Perform Health Check.
Unless you have reset the level, Health Check is performed at the Interface Test level. Refer to Table
3 .
A message posts in the Status/Message area if the test is successful, For example, Successful Health
Check is displayed in this area.
Configuring Health Check
You can configure Health Check settings.
1 Right-click an appliance in the navigation panel or the graphical panel.
2 Select the Health Check menu, then select Health Check Settings.
The default tab is the Level tab. See Table 3
on page 102. Options on this tab allow you to choose how
thorough the health check will be when it is performed.
3 When you are satisfied with the level, select OK.
If you decide not to change the health check level settings, select Cancel.
Table 3 Health Check Levels
Level Name Functionality
None Health check disabled
Basic Function Check power supply and temperature status
Interface Test Everything from Basic level in addition to checking all interfaces
Device Test Everything from Interface Test level, in addition to performing a Device
Inquiry on each target device
Device Ready Everything from Device Test level, in addition to performing a Test Unit
Ready on each target device (non-removable media only)
Note
Health check levels in AMC are not identical to the health check levels used by
the library management clients for the i-platform libraries.