Appendix B Fault Symptom Code (FSC) Dictionary
ATL M-Series User’s Guide 129
261F FSC_SERVO_SHUTTLE_
SENSOR_FAILURE
The box's shuttle
sensor was not
detected during shuttle
calibration
2620 FSC_SERVO_NVR_
SHUTTLE_DATA_
INVALID
Shuttle NVR data has
been corrupted, or not
yet initialized
2621 FSC_SERVO_X_AXIS_
JAMMED
The X axis cannot be
moved properly in
either direction
2622 FSC_SERVO_FAILED_
TO_RAISE_DRIVE_HUB
The drive hub could
not be raised into
position on cartridge
load
2623 FSC_SERVO_
CARTRIDGE_STILL_
LATCHED
The cartridge is still
being retained by the
drive
2624 FSC_SERVO_CLEANER_
SLOT_NOT_
ACCESSIBLE
The (NVR spec'd) XY
build does not provide
access to the cleaner
slot
XY
NVR
50%
50%
2625 FSC_SERVO_SHUTTLE_
NOT_CALIBRATED
The shuttle's vertical
position is still
unknown
2626 FSC_SERVO_THETA_
CALIBRATION_ERROR
The Theta angles are
out of specification
after calibration
attempt
2627 FSC_SERVO_X_
CALIBRATION_ERROR
The X axis did not
travel the minimum
distance when
calibrating
FSC Name Description FRU Name Confidence %