Scalar 100 User’s Guide 99
13 xx
Cannot read barcode label or the label is bad.
Ensure that the barcode label was supplied by ADIC or an ADIC approved
vendor.
Check the cartridge labels to ensure that they meet specifications, are properly
installed, and not damaged or dirty. The cartridge slots in question are displayed
with the Service Action Code.
Ensure that scan beam is not obstructed.
Retry the failing operation.
Power off and on the Scalar 100 library to recover from the error. Use the rear
switch to perform this action, wait at least one minute between power off and
on.
Contact ATAC.
14 xx
The system detects that the serial number is missing from its NVRAM.
Locate the sytem serial number and write it down. Enter the system serial
number (Using serial cable and HyperTerminal). Enter “setser” command from
the HyperTerminal prompt.
Contact ATAC.
15 xx
An intermittent scanning error was detected. During demo, the library
performs inventory after each complete demo cycle and detects a
mismatch between the number of cartridges scanned and its previous
database.
Note the number of cartridges installed in the library and use the operator panel
to compare this information with the number of cartridges reported by the
library. Examine the cartridges that are installed but not reported by the library
for proper cartridge labels, replace the labels if necessary. Note that if a whole
column of cartridges is missing, the column fiducial label can be defective, in
this case the whole storage column must be replaced.
If all labels are correct, clear the SAC and retry the demo program (at least five
cycles).
Contact ATAC.
21 xx
NVRAM failures.
Check the library configuration and re-enter all data (SCSI ID, time/date, library
serial number, etc.). For instructions on how to do this, refer to
Configuring your
Library on page 67.
Power off and on the Scalar 100 library a few times and see if the same error
conditions re-appear. Use the rear switch to perform this action, wait at least
one minute between power off and on.
Contact ATAC.
Table 8 Service Action Code Descriptions
Reported
SAC
Error and Solution