Quantum DLT 7000 Manual Pagina 194

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 312
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 193
SCSI Commands
5-90 Quantum DLT 7000 Tape System
MODE SELECT (6) / (10) Command (15h) / (55h) (continued)
5.9.9 EEPROM Vendor Unique Page (3Eh)
The drive supports a vendor unique page that enables a user to modify savable
parameters. Only one savable parameter may be changed per Mode Select
command.
Bit
Byte
7 6 5 4 3 2 1 0
0 PS Rsv’d Page Code (3Eh)
1 Additional Page Length
2 ASCII String of Parameter Name and Value
Figure 5–44 EEPROM Vendor Unique Page - Data Format
The ASCII string has a parameter name, followed by one or more space
characters, a parameter value, and an ASCII line feed or null character. When
the string is parsed, the parameter value is interpreted as shown in the following
table. Note that the parameter name may be in upper or lower case. The savable
parameters are saved over resets and power cycles.
Vista de pagina 193
1 2 ... 189 190 191 192 193 194 195 196 197 198 199 ... 311 312

Comentarios a estos manuales

Sin comentarios