Quantum DLT 7000 Manual Pagina 241

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 312
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 240
SCSI Commands
Quantum DLT 7000 Tape System 5-137
5.15 READ POSITION COMMAND (34h)
The READ POSITION command is used to read a position identifier or SCSI Logical
Block Address (LBA). The LOCATE command uses this identifier to position back to
this same logical position in a high-performance fashion.
Bit
Byte
7 6 5 4 3 2 1 0
0 Operation Code (34h)
1 Logical Unit Number Reserved BT
2 - 8 Reserved
9 Unused Reserved Flag Link
Figure 5–67 READ POSITION Command Descriptor Block - Data Format
Table 5–65 READ POSITION Command Descriptor Block - Field Descriptions
Field Name Description
BT Block Type. This bit indicates how the position is to be interpreted. Since the
tape drive uses the same logical block regardless of the setting of this bit, the
setting is ignored. The logical block address values include all recorded objects:
blocks and filemarks.
NOTE
The drive returns CHECK CONDITION with UNIT NOT READY sense
key with the READ POSITION command if the media is not ready to
be accessed.
Vista de pagina 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 311 312

Comentarios a estos manuales

Sin comentarios