Quantum DLT-S4 Guía de usuario Pagina 241

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 386
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 240
Chapter 4 SCSI Commands
MODE SENSE (6) / (10) Command (1Ah / 5Ah)
DLT-S4 Interface Reference Guide 207
EEPROM Mode Page (3Eh) 4 This page returns all of the EEPROM parameters that can be set with the
MODE SELECT EEPROM page; it sometimes returns an error message in
the returned ASCII string.
The 10-byte
MODE SENSE command for the EEPROM page returns data
in the form of a
MODE SENSE (10) data header followed by block and
page descriptors.
Figure 107 EEPROM MODE
SENSE Page — Data Format
As with other MODE SENSE pages, the data in the page descriptor is
organized in the form of a parameter header followed by the parameter’s
value. The parameter is as follows:
Name T Current Default Minimum Maximum
Table 113 lists the parameter definitions:
Table 113 EEPROM MODE
SENSE Page Command
Descriptor Block — Field
Descriptions
Bit
Byte
7 6 5 4 3 2 1 0
0 PS (0) SPF (0) Page Code (3Eh)
1 Page Length
2 — n ASCII String of Parameter Name or Value
Field Description
Name Refers to the parameter name, for example,
ProductID or DefaultCompOn.
T Type. Designates data type; “b” indicates binary,
“A” indicates string type, no designator indicates
that the data is in decimal format.
Current, Default,
Minimum, and
Maximum
Specifies the current, default, minimum, and
maximum values of the parameter.
Vista de pagina 240
1 2 ... 236 237 238 239 240 241 242 243 244 245 246 ... 385 386

Comentarios a estos manuales

Sin comentarios