Chapter 7 Emission and Immunity Specifications
Immunities
DLT-V4 Product Specification 30
Table 34 Magnetic Field
Immunity Limits
Voltage Dips, Short
Interruptions, and
Variations Immunity
7
The tape drive meets the AC dips, interruptions, and variations
immunity limits per EN 61000–4–11: 2004 listed in table 35
.
Table 35 Voltage Dips, Short
Interruptions, and Variations
Immunity Limits
Specification Performance Criteria
50 Hz, 10 Amps per meter (A/m) No errors allowed
Specification Performance Criteria
95% Vreduction 10 milliseconds per
0.5 periods (Dips)
Soft recoverable errors allowed
30% Vreduction 500 ms per 25
periods (Dips)
Operator intervention allowed
95% Vreduction 5 sec per 250
periods (Interruptions)
Operator intervention allowed