For Your Safety
page 3 - 6 Operator Guide 599 DOC C00 003
3.6.2 <EMERGENCY STOP> Buttons
Information
The yellow luminous push-button <CONTROL OFF> on the operating panel
has the same function as the <EMERGENCY STOP> button.
All <EMERGENCY STOP> buttons (I/O unit …) have the same function: EMER-
GENCY STOP switches off the output electronics. All movements of the handling
unit and the storage towers stop immediately.
When persons or property are at risk immediately press the nearest <EMER-
GENCY STOP> button.
Moving parts stop at once.
WARNING!
Hazardous Voltage!
Pressing an <EMERGENCY STOP> button will not render the entire
AML/E system voltageless. Only the drive amplifiers are switched off.
Emergency stop does not switch off:
• the control units of the handling unit and the storage towers
• the AMU processor
• the drives
• the compressed air supply
Cut the power supply to these components at a suitable point (e. g. connecting plug
or switch)!