Operating The AML/E System
page 5 - 30 Operator Guide 599 DOC C00 003
5.5.2 Starting after an EMERGENCY STOP
WARNING!
Movements of system components in the archive can cause severy injury.
Before releasing an <EMERGENCY STOP> push-button and before re-star-
ting the AML/E system ensure that persons or property are not endangered!
a) Eliminate the cause of the EMERGENCY STOP.
b) Release the <EMERGENCY STOP> push-button (turn it left).
ATTENTION!
Upon the start of the system the handling unit automatically carries out a
reference movement. During the reference movement all axes of the handling
unit and the storage towers move.
Objects and system components within the reach of the axes can be damaged.
c) Start the system
( “Starting The AML/E System (Starting "AUTO")” page 5/25).