Chapter 5 Running Your Library
Understanding Location Coordinates
Scalar i6000 User’s Guide 299
I/O Blade Locations 5
The LMC displays I/O blade locations in parenthetical format. For
example, see the Connectivity dialog box in figure
36. The location for the
first I/O blade listed in the Co
nnectivity dialog box is reported as
(1,1,1,1,3). The location coordinates see aisle, module, rack, cluster, and
bay. By reading the numbers backwards, you can determine that the
location of the I/O blade is in bay 3 of the control module’s I/O
management unit. In figure
37 on page 300, its bay (1,1,1,1,3) is shaded
gray. This figure shows the numbering sequence
and the bay positions in
the I/O management unit.
Figure 36 I/O Blade Location
Coordinates
I/O blade location
coordinates