Quantum Scalar 10K Instrucciones de operaciones Pagina 232

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 324
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 231
4-154 Menus and Commands
6-00058-05 Rev A
Library Submenu
Path: Main Menu Service Diags Library
Use the Library Submenu to perform move tests. See Figure 4-
239.
Figure 4-239 Library Submenu
Storage Move
Path: Main Menu Service Diags Library Storage
Move
Use Storage Moves to move a cartridge through every storage
cell in a given range. The cartridge is moved to or from the I/
E station and then to the specified cells. This test requires a
service-level password. After a password is provided, the
system prompts for the I/E station where the source cartridge
is located. Then, the system prompts for the beginning and
ending storage location. The test can be cancelled at any. See
Figure 4-240.
Figure 4-240 Storage Moves Dialog
Parameters Description
Cell Beginning and ending storage
locations
Status Shows the status of the test
(Running, Canceled)
Cancel Y to cancel the test
N to continue running the test
> Storage Move...
Corner Moves...
STORAGE MOVE TEST
Cell: 01 A 2 10
Status: Running
Cancel: N
Note
If the operation
stops, the Cancel
parameter no
longer displays.
Vista de pagina 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 323 324

Comentarios a estos manuales

Sin comentarios