6
Scorpion 240 Product Manual
MOUNT HOLE
M3 (4 PLACES)
86
± 0.25
1.8
± 0.25
7.0
± 0.3
45.5
± 0.25
203.2
± 0.25
79.5
± 0.25
11.9
± 0.3
82.6
± 0.6
21.8
± 0.3
45.5
± 0.25
M3 (4 PLACES)
MOUNTING HOLE
149.6
± 0.25
203.2
± 0.5
79.5
± 0.25
139.7
± 0.3
146 +1
.5 –0.5
1.8
± 0.25
224.0 max
224.0 max
Figure 3. Internal Scorpion 240 Drive—Dimensions
Power Specifications
Internal drive
The following table lists the power specifications for the internal Scorpion 240 drives.
Specification +12 VDC supply +5 VDC supply
Voltage Tolerance + or – 10% + or – 7%
Operational Current 700 milliamps max 1.70 Amps max
Standby Current 500 milliamps max 1.0 Amps max
Surge (peak) 2400 milliamps max 2.0 Amps max
Ripple (peak-to-peak)
100 mV
100 mV