78 Quantum|ATL PowerStor L500 Series Tape Library User’s Guide
Electromagnetic
Interference (EMI)
Susceptibility
5
Emission standards and limits are as follows:
EMI Emissions
5
• FCC Part 15B, Class A(US/Canada)
• EN55022, Class A/EN50082-1 (CE Mark)
• VCCI, Class A (Japan)
• AS/NZS 3548, Class A (Australia/New Zealand)
Conducted Emissions
5
Table 19
lists the conducted emission limits.
Table 19 Conducted
Emission Limits
Radiated Emissions
5
Table 20
lists the limits of radiated interference field strength, in the
frequency range from 30 MHz to 1000 MHz at a test distance of 10
meters, for Class A equipment.
Table 20 Radiated
Emissions (30 MHz to
1000 MHz)
Frequency Range =
0.15 to 30 MHz
Limits dB
Quasipeak Average
0.15 to 0.050 79 66
0.50 to 30 73 60
Frequency Range = 30 MHz to
1000 MHz
Quasi-Peak Limit dB (uV/m)
@ 10 meters
30 MHz to 230 MHz 40
230 MHz to 1000 MHz 47