Quantum SDLT 320 Guía de usuario Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 102
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
SDLT 220 and SDLT 320 Design & Integration Guide CHAPTER 2: General Drive Specifications
81-81148-01 March 2004 2-17
2.7 Environmental Requirements
The SDLT tape drive operates in environments that include general offices and
workspaces with systems capable of maintaining standard comfort levels.
The following sections provide the operating, non-operating, storage and shipping
environmental specifications for the SDLT tape systems (both the internal and the
shoebox configurations). For long-term trouble-free operation, it is strongly
recommended that DLTtape systems be used in a clean, smoke-free environment.
Table 2-10. DLTtape Media Operating and Storage Limits
Operating
Conditions
Temperature 10°C to 40°C (50°F to 104°F)
Relative Humidity 20% to 80% (non-condensing)
Storage Conditions With Data: Without Data:
Temperature 18°C to 28°C (64°F to 82°F) 16°C to 32°C (61°F to 89°F)
Relative Humidity 40% to 60% (non-condensing) 20% to 80% (non-condensing)
Shipping Conditions
Temperature -18°C to 49°C (0°F to 120°F)
Relative Humidity 20 to 80% (non-condensing)
Maximum Wet Bulb
Temperature
26°C (79°F)
Maximum Dew Point 2°C (36°F)
Vista de pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 101 102

Comentarios a estos manuales

Sin comentarios