SDLT 220 and SDLT 320 Design & Integration Guide CHAPTER 7: Updating the Firmware
81-81148-01 March 2004 7-3
NOTE: The Firmware Upgrade will fail the microcode update
process if the firmware personalities do not match; this
will be noted in the history log, along with the reason for
the failure.
7. Wait several minutes for the update process to complete. The Amber and
Green LEDs will blink the entire time that memory is being updated.
8. When the update is complete, the drive resets itself and goes through POST.
The tape is rewound, unloaded, and ejected from the drive. SCSI status will
indicate that microcode has been updated (06h, 3F, 01).
NOTE: If the drive is mounted in a tape automation library, the
tape is not automatically ejected, but it is rewound to BOT
and unbuckled in preparation for unloading.