CHAPTER 2: General Drive Specifications SDLT 220 and SDLT 320 Design & Integration Guide
2-20 March 2004 81-81148-01
2.7.5 Particulate Contamination Limits
The ambient operating environment for the tape drive may not exceed the
particulate counts shown in Table 2-13.
Table 2-13. Particulate Contamination Limits
Particle Size
(microns)
Number of Particles
Particle Size per Cubic
Meter
Number of Particles
Particle Size per Cubic
Foot
0.1
8.8 x 10
7
2.5 x 10
6
0.5
3.5 x 10
7
1.0 x 10
6
5.0
2.5 x 10
5
7.0 x 10
3