CHAPTER 2: General Drive Specifications SDLT 220 and SDLT 320 Design & Integration Guide
2-18 March 2004 81-81148-01
2.7.1 Temperature and Humidity
The ambient operating environment for the tape drive may not exceed the limits
shown in Table 2-11. (The specifications shown in the table are valid for both the
internal and tabletop tape drives.)
2.7.2 Air Flow Requirements
Adequate air flow must be provided for the internal unit to dissipate the heat
resulting from drive operation (see Chapter4, Thermal Specifications for more
details about temperatures inside the drive, and illustrations showing where air
flow and various temperatures are measured). The air flow must be sufficient to
keep the tape path temperature below 52°C.
NOTE: It is important to realize that the amount of air flow
provided for the tape drive determines the maximum
ambient temperature in which the drive can operate.
Table 2-11. Temperature and Humidity Specification
Specification Operating Limits
Non-Operating Limits
(Power On; No Tape Loaded)
Wet Bulb Temperature 25°C (77°F) 25°C (77°F)
Dry Bulb Temperature
Range
10°C to 40°C (50°F to 104°F) 10°C to 40°C (50°F to 104°F)
Temperature Gradient 11°C (20°F) / hour (across range) 15°C (27°F) / hour (across range)
Relative Humidity 20% to 80% (non-condensing) 10% to 90% (non-condensing)
Humidity Gradient 10% / hour 10% / hour