Vista de pagina 116
Data Cartridge Write-protect Switch
SDLT 600 Product Manual 101
Table 37 Write-Protect Switch
Positions
Write-protect
Switch Position
Orange
Write-protect
Indicator Result
Before Loading the Data Cartridge
Enabled
(Slide switch to
left)
Visible You cannot write data to the
media. You cannot overwrite
existing data on the media.
You cannot append
additional data to the media.
Disabled
(Slide switch to
right)
Not Visible Unless the data cartridge is
write-protected via firmware:
- You can write data to the
media.
- You can overwrite existing
data on the media.
- You can append additional
data to the media.
After Loading the Data Cartridge and During Operation
If you move the
write-protect
switch from its
right (disabled)
position to its left
(enabled)
position
Visible If the tape drive is currently
writing to a data cartridge,
the write-protect feature does
not take effect until
after the
current write operation
completes.
If you move the
write-protect
switch from its
left (enabled)
position to its
right (disabled)
position
Not Visible The data cartridge becomes
write-enabled
after a variable
amount of seconds.