Chapter 2 SDLT 600 Tape Drive Specifications
Functional Specifications
SDLT 600 Product Manual 26
(The power drawn in these two modes is similar enough that they are
listed together.)
Table 16 Current and Power
Requirements (SCSI Interface)
Note: In table 16 and table 17, the current and DC power values
pertain to the internal tape drive, while the AC power values
apply to the tabletop tape drive.
Mode
5 V Current (A)
MaxPk
1
MaxMean
2
Typ
3
12 V Current (A)
MaxPk
1
MaxMean
2
Typ
3
DC Power
(W)
Max
4
Typ
5
AC Power
(W)
Max
6
Typ
7
Standby/Idle 2.6 2.6 2.4 0.2 0.1 0.1 14 14 47 45
Media Loading/
Unloading
6.2 5.3 3.4 2.7 0.9 0.7 30 26 64 56
600 Write– Motor
Start
8
4.3 4.0 3.7 1.3 0.3 0.3 23 22 51 48
600 Write–
Streaming
5.4 5.1 4.9 0.7 0.5 0.4 30 30 65 63