9-68 6-00667-01 Rev B
Scalar 100
3. Select OK.
4. With New start slot selected, press OK.
5. If you did not choose to modify the start slot, the exercise runs. If you chose to select a new
start slot, do the following:
a. With Select Column selected, press Change Column until the arrow points to the start
column. Press Next.
b. With Magazine selected, select Change Magazine until the arrow points to the start
magazine. Press Next.
c. With Slot selected, press Change Slot until the arrow points to the start slot.
The Select SOURCE line displays the start slot. For example, the display below has slot 2A4
selected as the source slot.
d. Select OK. The exercise is run.
6. When the exercise is complete, a report displays.
Opening/Closing and Extending/Retracting
Use Step to manipulate the open/close and reach/retract features of the picker fingers.
Path: Main menu > More > Service > Library > Diags > Fingers > Step
To exercise the picker fingers
1. From the Main menu, select More and then select Service. Select Library and then select
Diags. Select Fingers and then select Step.
A dialog is displayed warning that only qualified personnel should operate this feature.
2. Select OK.