General Description and Specifications
Quantum DLT 8000 Tape System 1-15
1.3.16 Electromagnetic Interference (EMI) Susceptibility
This section presents tables that provide the specifications for conducted emissions,
radiated emissions, magnetic radiated susceptibility, radiated susceptibility, conducted
susceptibility, and ESD failure limits.
Regulations and certifications for the tape system include:
For electromagnetic emissions:
• CSA 108.8
• EEC Directive 89/336
EN55022 and national standards are based on:
• BS6527 (UK)
• NEN55022 (Netherlands)
• VDE 0971 Class B (Germany)
• CE Mark
Cispr22 Class B:
• FCC Rules Part 15B
• Class B Certification
Table 1−14 Conducted Emissions
NOTE
Limits for Class B equipment are in the frequency range from 0.15 to 30 MHz. The
limit decreases linearly, with the logarithm of the frequency in the range from 0.15 to
0.50 MHz.
Frequency Range (MHz) Limits (dB)
Quasi-Peak Average
0.15 to 0.05 66 to 56* 56 to 46
0.50 to 5 56 46
5 to 30 60 50
* The limit decreases with the logarithm of the frequency.