2.2.3 Setting Parity Checking
Parity checking is the default setting for DLT 8000 tape systems. If the system to which
you are configuring the tape system does not generate parity, disable parity checking on
the tape system by installing a jumper block on pin pair 1 / 2 on the connector as shown
in Figure 2-3. Note that this is the same connector as the one used to select the setting
for TERM PWR (Section 2.2.2).
Figure 2–3 Jumper Installed on Pin Pair 1 / 2 Disables Parity Checking