Operation and Maintenance 53
Causes of the Use Cleaning Tape Warning
The most common reasons that the Use Cleaning Tape LED gets turned on for, in order of
highest rate of occurrence, are listed below:
Dirty ("Stained") heads.
A cleaning cycle must be executed to clear this indication.
Worn tape.
DLT tapes are rated at 500,000 passes. Applications that overwrite small blocks of data
cause "shoe shining" of the tape against the head and will reach the 500,000 passes sooner
than might be expected.
Bad environment.
Data errors result from a number of factors, each of which subtract from the margin
between good data recovery and an error. High levels of dust contamination, high
humidity, and heat can be significant factors.
Worn heads.
The tape heads will eventually wear out causing the time between cleanings to get shorter
and shorter. The DLT2000XT, DLT4000, and DLT7000 drives have an MTBF rating of
30,000 hours.
Cleaning the Enclosure
The outside of the enclosure can be cleaned with a damp towel. If you use a liquid all-purpose
cleaner, apply it to the towel. Do not directly spray the enclosure.