Pathlight VX Site Preparation Guide 49
Use Table 34 to record the model and firmware information about the aggregation device.
Follow these guidelines when connecting an aggregation device:
• The aggregation device must be dedicated exclusively to a Pathlight VX physical library. The
aggregation device cannot be used for Inter-Switch Link (ISL) connections to customer SANs.
• If the device is zoned, the zone must allow access between Pathlight VX I/O blades, the physical
library controller, and any of the respective drive resources.
• Physical drives and libraries dedicated to Pathlight VX can be attached only to internal switch ports
12, 13, 14 (not used as ISLs to aggregation switches).
• Aggregation devices can connect only to the FCB1-FC6 and FCB2-FC6 ports.
• Both Pathlight VX I/O blades and the Pathlight VX MS HBA must be mapped from the physical
library to have access to all physical library controllers and drive LUNs.
• When mapping multiple partitions from a physical library to each Pathlight VX FCB and the MS
HBA, the strategy must always map the drive members after each respective partition to ensure
Pathlight VX can properly associate the correct drive members to the correct physical library.
• When Disk Extension Tape (DET) policy management is enabled, best practice is to dedicate a
partition for DET media. This partition should not have more than four drives.
Table 34 Aggregation Device Model Information
Description Model Information
Aggregation Device Model:
Aggregation Device Manufacturer:
Aggregation Device Firmware:
CAUTION
The aggregation device must be dedicated to the Pathlight VX; it
cannot be used as an aggregation device for the broader fabric
domain, even when the device is zoned. Any non-compliance with
this guideline could result in the loss of data.
CAUTION
If the components of the Pathlight VX cannot communicate as
described in this guideline, the Pathlight VX will not function.
CAUTION
The aggregation device must not be connected to a Pathlight VX
internal switch.
Note
When you configure port 6 on the FC blade to communicate with an
aggregation device, the Connection Options field must be set to Point to
Point. Refer to "Configuring FC Port Parameters" in Pathlight VX
Installation Guide.
Note
Consult "Configuring a Physical Library for a Pathlight VX" in Pathlight VX
Installation Guide for cabling information.