Chapter 8: Installing, Removing, and Replacing Components
Removing and Replacing the System Control Board
228 Quantum Scalar i40 and Scalar i80 User’s Guide
12 Go to the operator panel and wait until the Setup Wizard appears
on the screen. The Setup Wizard screen may take up to 20 minutes
to appear.
13 Continue as follows:
• If you have saved a library configuration that you want to
restore on the library, go to:
Restoring the Library Configuration
on page 228.
• If you do NOT have a saved library configuration to restore on
the library, go to:
Manually Reconfiguring the Library on
page 229.
Restoring the Library
Configuration
Follow the instructions in this section if you have a saved library
configuration that you want to reinstall on the library.
1 On the operator panel, press Cancel to exit the Setup Wizard.
2 Take note of the library’s IP address (on the operator panel, select
Reports > Network Settings).
3 Access the Web client using the IP address and log in using the
default user name and password:
• User name: admin
• Password: password
Note: Once you restore the configuration, all your former user
names and passwords are restored.
4 Restore the configuration using the Web client as follows:
a Select Tools > Save/Restore Configuration.
b Select Restore System Configuration.
c Click Browse. Navigate to the saved configuration and click
Open.
d Click Apply
e Click OK.
Note: Restoring the configuration does NOT restore your network
settings.