Chapter 8: Installing, Removing, and Replacing Components
Packaging the Library for Moving or Shipping
Quantum Scalar i40 and Scalar i80 User’s Guide 239
WARNING: Two people are required to safely remove the
library from the rack.
To remove the library from a desktop kit, remove the two top
cover screws. Loosen the captive thumbscrews on the library
chassis that are attached to the side panels of the desktop kit.
Slide the side panels one inch toward the rear of the library,
then pull the side panels off.
9 Make sure the robot is sitting on the floor of the library as follows:
Look inside the library through one of the magazine openings. If the
robot is not sitting on the floor of the library, reach inside and
gently press down on one of the robot’s metal side rods until the
robot starts moving. It should drift down to rest on the floor of the
library.
10 Reinstall the empty magazines in the library by pushing them in
until they stop.
11 If you removed the tape drives earlier, reinstall them in their proper
slots. Push them carefully into their slots and tighten the captive
thumbscrews.
12 Restrain the robot as follows (see Figure 61 on page 240):
a Turn the library carefully on its side (either the left or right side).
Make sure the front end of the library (the “rack ear”)
overhangs the edge of the table so that the library lies flat.
Caution: Do not turn the library upside down. Do not turn
the library more than 90 degrees from upright.
b Install four thumbscrews into the floor of the library in the
locations shown in
Figure 61 on page 240. They will screw
through the robot and hold it in place on the floor of the library.