Chapter 4: Configuring the Library
Configuring Cleaning Slots
62 Quantum Scalar i40 and Scalar i80 User’s Guide
Note: If the library contains zero import/export (I/E) station slots, you
will not be able to import or export cleaning cartridges. See
Configuring I/E Station Slots on page 63 for more information.
Note: This operation should not be performed concurrently by
multiple administrative users logged in from different
locations. You can access the screen, but you cannot apply
changes while another administrative user is performing the
same operation.
Operator Panel
1 Select Setup > Dedicated Slots > Cleaning.
2 Press Modify.
3 Use the Up and Down buttons to select a value from zero to 4.
4 Press Apply.
5 Press Exit.
6 Save the library configuration (see Saving the Library Configuration
on page 101).
Web Client
1 Select Setup > Cleaning Slots.
2 Under the New Settings column, select the number of cleaning
slots to configure.
3 Click Apply.
4 Save the library configuration (see Saving the Library Configuration
on page 101).