Chapter 5 Administration
Configuring the Autoloader
62 Quantum SuperLoader 3 User’s Guide
Note: The front panel requires a six-digit password to change the
configuration (see “
Setting Passwords” on page 74). The LCD
front panel default password for the Administrator is
000000.
The default password for the Operator is 111111.
• If the autoloader does not power on successfully, check the
following:
• Power switch is on.
• Power cable is inserted correctly.
• SCSI (or SAS, or Fibre Channel) cable is connected to the
autoloader and host computer.
• SCSI bus is terminated (SCSI autoloader).
• No error code displays on the autoloader LCD.
• If you cannot resolve the problem yourself, contact your service
representative or go to www.quantum.com
.
When you first power on the autoloader, the setting for the Internet
Protocol (IP) address is static with the address
192.168.20.128. If you
want to use Dynamic Host Configuration Protocol (DHCP) to change the
IP address, see “
Setting the IP Address” on page 67. To determine the IP
address when using DHCP, view the Ethernet status information (see
“
Viewing Ethernet Information” on page 40).
Configuring the Autoloader
To configure the autoloader, start with the main menu on the front
panel. If the main menu is not already visible on the LCD, press
Enter.
When you first power on the autoloader, the default is set with no
password protection. However, after you set the security option, all the
configuration functionality is password-protected. You need an
administrator-level password to configure the autoloader.
To configure the Quantum SuperLoader 3 autoloader, you must verify
the setup of the following:
• SCSI, SAS, or Fibre Channel autoloader.