Quantum Scalar 50 LTO-3HH Guía de usuario Pagina 191

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 290
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 190
Chapter 5 Troubleshooting
Common Problems and Solutions
Quantum Scalar 50 User’s Guide 167
Table 33 Robotics (Hand)
Problems
Problem Corrective Action
The robot does not
move at power up.
Make sure that all internal packing materials
(foam pads and metal straps) have been
removed.
Check the library state on the OCP or remote
management pages. If Door Open is
displayed, make sure the front doors are
closed.
Physically remove the AC power by removing
all power cords from the power supply(s) and
reconnect them. Power the library on and if
the robot still does not move, contact an
authorized Quantum field service engineer
(see “Contacts”
on page xx).
The barcode reader
cannot read the
barcode and
displays “no
label”.
Verify that nothing obstructs the reader.
It is recommended to avoid barcode reader
problems, to only use tape cartridge labels
provided by manufacturer.
Reboot the library (see “Reboot Library”
on
page 126). If the problem continues, contact an
authorized Quantum field service engineer
see “Contacts”
on page xx).
The robot times
out or fails during
an operation.
Check that the tape cartridge involved in the
operation is properly positioned in the slot or
drive and ready to be picked.
Check that the robot is not obstructed in any
way.
Retry the operation. If it still fails, contact a
field service engineer.
Vista de pagina 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 289 290

Comentarios a estos manuales

Sin comentarios