Appendix C Installing the Scalar 50 Library
Installing the Library
Quantum Scalar 50 User’s Guide 198
Installing the Library Chassis
Warning: The Scalar 50 weighs approximately 65
lbs (29 kg) without
power supplies or tape drives. At least two people are
required to lift and install either library.
3
1 The back mounting brackets are lettered (A through I so the correct
mounting position is easily determined. The mounting positions
differ depending on the depth of the rack (see
table 52).
Table 52 Back Mounting
Bracket Orientation
Once the location is determined, attach the back brackets to each side of
the library with four M5 x 8 Allen screws (see figure
107)
Rack Depth Mounting Position
>27 to 28
in. Use holes A and C
>28 to 29 in. Use holes B and D
>29 to 30 in. Use holes A and C
>30 to 31 in. Use holes B and D
>31 to 32 in. Use holes C and E
>32 to 33 in. Use holes D and F
>33 to 34 in. Use holes E and G
>34 to 35 in. Use holes F and H
>35 to 36 in. Use holes G and I
Note: Use the shortest depth number. For example, if the
measurement is 34 in., use holes E and G.