Bugcheck Error Logs (SDLT 600 only)
Quantum SuperLoader 3 User’s Guide 147
Bugcheck Error Logs (SDLT 600 only)
Bugcheck Error logs typically indicate that the firmware has reached a
point in the decision process that requires a drive reset. There are 11
bugchecks, indicated by the Bugcheck Error field found in the event
log's first line. The following conditions may cause a bugcheck:
• Hardware errors
•Media errors
• Power supply problems
• External conditions (shock, vibe, hot, cold, and so on)
• Firmware problems
Note: Typically, firmware problems are not the cause and you should
check for other sources. If it is determined to be a firmware
issue, contact customer support.
14/00
Entity Not Found. A logical block
that was written on the tape was
not found while trying to read the
data.
• Problem may be the tape cartridge or the
drive. Check drive logs to correlate events that
may have led up to this condition.
• If the problem continues, contact customer
support.
47/00
SCSI Parity Error. SCSI bus
communications problem.
• Check SCSI cables, terminators, and all
devices attached to the SCSI bus.
80/01
Cleaning Required. The drive has
detected a condition in which a
cleaning tape must be used. (SDLT)
• Use a cleaning tape and/or different media.
Check drive logs to review related events. If
this persists with multiple media after
cleaning, the drive may need to be replaced.
If all related to one piece of media, replace
that tape cartridge.
• If the problem continues, contact customer
support.
ASC/ASCQ Description Suggested Action