LOG SENSE Command (4Dh) SDLT 600 SCSI Interface Guide
4-60 January 2005 81-81200-02 REV A01
Counter Value Parameter codes 02h through 09h provide a count of the number of bytes
transferred since the last time the counters were reset with a LOG SELECT
command or reset condition.
Parameter Codes 02h and 03h
— Report the count of bytes transferred from
the drive to the initiator. Parameter code 02h reports the number of full
megabytes transferred; parameter code 03h reports the number of bytes less
than a full megabyte transferred. Multiplying the counter returned for
parameter code 02h by 1,048,576 and then adding the value of the counter
returned by parameter code 03h results in the actual total bytes transferred
to the initiator.
Parameter Codes 04h and 05h
— Report the count of bytes transferred from
the drive to the buffer. Parameter code 04h reports the number of full
megabytes transferred; parameter code 05h reports the number of bytes less
than a full megabyte that have been transferred. Multiplying the counter
returned for parameter code 04h by 1,048,576 and then adding the value of
the counter returned by parameter code 05h results in the actual total bytes
transferred from tape to the buffer.
Parameter Codes 06h and 07h
— Report the count of bytes transferred from
the initiator to the buffer. Parameter code 06h reports the number of full
megabytes transferred; parameter code 07h reports the number of bytes less
than a full megabyte that have been transferred. Multiplying the counter
returned for parameter code 06h by 1,048,576 and then adding the value of
the counter returned by parameter code 07h results in the actual total bytes
transferred from the initiator to the buffer.
Parameter Codes 08h and 09h
— Report the count of bytes written to the
drive. Parameter code 08h reports the number of full megabytes transferred;
parameter code 09h reports the number of bytes less than a full megabyte
that have been transferred. Multiplying the counter returned for parameter
code 08h by 1,048,576 and then adding the value of the counter returned by
parameter code 09h results in the actual total bytes written to the drive.
Table 4-36. Log Parameters for Read / Write Compression Ratio LOG SENSE Page — Field
Descriptions (Parameter Codes 02h through 09h) (Continued)
Field Name Description