SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-191
LOCU Logical Object Count Unknown. When set to 1, indicates that the
value contained in the Number of Logical Objects in Object Buffer
field does not accurately represent the actual number of logical objects
in the object buffer. When set to 0, indicates that the value contained in
the Number of Logical Objects in Object Buffer field is accurate.
BYCU Byte Count Unknown. When set to 1, indicates that the value
contained in the Number of Bytes in Object Buffer field does not
accurately represent the actual number of bytes in the object buffer.
When set to 0, indicates that the value contained in the Number of
Bytes in Object Buffer field is accurate.
LOLU Logical Object Location Unknown. When set to 1, indicates that the
values contained in the Partition Number, First Logical Object Loca-
tion, or Last Logical Object Location fields are not known or accurate
reporting is not currently available. When set to 0, indicates that the
values these fields contain are accurate.
PERR Position Error. When set to 1, indicates that the drive is unable to
report the correct position as a result of an overflow in any of the
returned positional data fields. When set to 0, indicates that there were
no overflow conditions in any of the returned positional data fields.
Partition Number The partition number for the current logical position.
First Logical Object
Location
The block address associated with the current logical position; the next
block to be transferred between the target and initiator if a READ or
WRITE command is issued.
Last Logical Object
Location
The block address associated with the current physical position; the
next block to be transferred to tape medium from the drive’s buffer. If
the buffer is empty, or has only a partial block, the same value as First
Block Location is reported. The first block or filemark written onto the
tape medium is at address 0.
Number of Logical
Objects in Object
Buffer
The number of data blocks in the drive’s buffer that have not been
written to the tape medium.
Number of Bytes in
Object Buffer
The number of data bytes in the drive’s buffer that have not been
written to the tape medium.
Table 4-111. READ POSITION (Short Form) Data — Field Descriptions (Continued)
Field Name Description