REPORT SUPPORTED OPERATION CODES Command (A3h) SDLT 600 SCSI Interface Guide
4-212 January 2005 81-81200-02 REV A01
4.25.2 One_command Parameter Data Format
The REPORT SUPPORTED OPERATION CODES one_command parameter data format contains
information about the CDB and a usage map for fields in the CDB of the command specified in the
Reporting Options, Requested Operation Code, and Requested Service Action fields of the REPORT
SUPPORTED OPERATION CODES CDB.
Figure 4-117. One_command Parameter Data — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 Reserved
1 Reserved Support
2 – 3
(MSB)
CDB Size (n – 3)
(LSB)
4 – n CDB Usage Data