SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-45
8002h Total dropout error count
8003h Total servo tracking errors
9000h-
9007h
Without substantial delay errors by channel
9080h-
9087h
Write only: Possible delay errors assignable to specific
channels
Read only: Raw sub-block read errors by channel
Note: Many of these errors are write, not read, errors and
are not to be included in read error-rate calculations.
If these errors are used to try to identify bad
channels, the bad channel may be on either the
writing or reading drive.
Note: Parameter codes 00h, 01h, and 04h always return a value of 0.
DU Disable Update. When set to 0, indicates that the drive updates all log
parameter values. When set to 1, indicates that the drive does not update
the log parameter values except in response to a LOG SELECT command.
The drive sets this bit to 1 when accumulated values reach maximum. The
drive also returns this bit set to 1 if the host set the bit in the last LOG
SELECT command. Default is 0.
Note that for parameter types other than threshold and cumulative values,
this bit is always set to 0.
DS Disable Save. Not supported. Always set to 1.
TSD Target Save Disable. Not supported. Always set to 1.
ETC Enable Threshold Comparison. When set to 1, indicates that the drive
performs comparison to threshold. When set to 0, indicates that the drive
does not perform the comparison. The Control Mode Page of the MODE
SELECT command sets this bit set to 1. Default is 0.
Table 4-24. Log Parameters for Read / Write Error LOG SENSE Page —
Field Descriptions (Continued)
Field Name Description