SDLT 600 SCSI Interface Guide Chapter 4: SCSI Commands
81-81200-02 REV A01 January 2005 4-35
Figure 4-16. LOG SELECT Log Page — Parameters Format
Bit
Byte
7 6 5 4 3 2 1 0
0 – 1
(MSB)
Parameter Code
(LSB)
2
1
DU DS TSD ETC TMC LBIN LP
3 Parameter Length (n – 3)
4 – n
(MSB)
Parameter Value
(LSB)
1. The byte 2 fields are collectively referred to as the Parameter Control byte.
Table 4-21. LOG SELECT Log Parameters — Field Descriptions
Field Name Description
Parameter Code Parameter codes supported for the READ / WRITE error counter pages are
as follows:
Code Description
0000h Errors corrected without substantial delays
0001h Errors corrected with possible delays
0002h Total read / write errors
0003h Total read / write errors
0004h Total times correction algorithm processed. Always 0 for write
errors only.
0005h Total bytes processed
0006h Total uncorrected errors
8000h WRITE errors since last READ (page 02) or
READ errors since last WRITE (page 03)
8001h Total raw write error flags
8002h Total dropout error count