LOG SELECT Command (4Ch) SDLT 600 SCSI Interface Guide
4-34 January 2005 81-81200-02 REV A01
4.7.3 LOG SELECT Log Page Format
Each log page begins with a 4-byte header followed by n number of log parameter blocks—one block
for each parameter code. Each block, except for parameter code 05h, comprises 8 bytes. The parameter
block for page code 05h is 12 bytes.
Figure 4-15. LOG SELECT Log Page — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 Page Code
1 Reserved
2 – 3
(MSB)
Page Length (n – 3)
(LSB)
Log Parameters
4 Log Parameter (First)
x + 3 Length (x)
.
.
n – y + 1 Log Parameter (Last)
n Length (y)
Table 4-20. LOG SELECT Log Page Header — Field Descriptions
Field Name Description
Page Code Specifies the log page to which this LOG SELECT command is directed.
Page Length Specifies the total number of bytes contained in this log page, not including the
4 bytes that make up the header.
Log
Parameters
Use one block for each parameter code.