READ POSITION Command (34h) SDLT 600 SCSI Interface Guide
4-190 January 2005 81-81200-02 REV A01
4.18.1 Read Position Data — Short Form
Data returned when the service action value is 00h or 01h takes the following form:
Figure 4-100. READ POSITION (Short Form) — Data Format
Bit
Byte
7 6 5 4 3 2 1 0
0 BOP EOP LOCU BYCU Rsv’d LOLU PERR Rsv’d
1 Partition Number
2 – 3 Reserved
4 – 7
(MSB)
First Logical Object Location
(LSB)
8 – 11
(MSB)
Last Logical Object Location
(LSB)
12 Reserved
13 – 15
(MSB)
Number of Logical Objects in Object Buffer
(LSB)
16 – 19
(MSB)
Number of Bytes in Object Buffer
(LSB)
Table 4-111. READ POSITION (Short Form) Data — Field Descriptions
Field Name Description
BOP Beginning of Partition. When set to 1, indicates that the drive is at the
Beginning of Partition (BOT) in the current partition. When set to 0,
indicates that the current logical position is not at BOT. Since SDLT
tape drives do not support more than one partition, the value of this bit
is 1 when at BOT.
EOP End of Partition. When set to 1, indicates that the drive is positioned
between early warning and the End of Partition (EOP) in the current
partition. When set to 0, indicates that the current logical position is
not between early warning and EOP.