Appendix B Fault Symptom Code (FSC) Dictionary
118 ATL M-Series User’s Guide
2032 FSC_SEAGATE_SCSI_
CMD_ERROR_7
Response packet
received from drive 7
indicates command
failed
Drive 100%
2033 FSC_SEAGATE_SCSI_
CMD_ERROR_8
Response packet
received from drive 8
indicates command
failed
Drive 100%
2034 FSC_HP_BUSY_1 Response packet
received from drive 1
indicates drive busy
Drive 100%
2035 FSC_HP_BUSY_2 Response packet
received from drive 2
indicates drive busy
Drive 100%
2036 FSC_HP_BUSY_3 Response packet
received from drive 3
indicates drive busy
Drive 100%
2037 FSC_HP_BUSY_4 Response packet
received from drive 4
indicates drive busy
Drive 100%
2038 FSC_HP_BUSY_5 Response packet
received from drive 5
indicates drive busy
Drive 100%
2039 FSC_HP_BUSY_6 Response packet
received from drive 6
indicates drive busy
Drive 100%
203A FSC_HP_BUSY_7 Response packet
received from drive 7
indicates drive busy
Drive 100%
203B FSC_HP_BUSY_8 Response packet
received from drive 8
indicates drive busy
Drive 100%
FSC Name Description FRU Name Confidence %