Appendix B Fault Symptom Code (FSC) Dictionary
124 ATL M-Series User’s Guide
241E FSC_LIBRARIAN_
ILLEGAL_BUILD_
DRIVE_FITTED
Drive 3 detected when
library configured for 5
drive operation
Microcode 100%
2500 FSC_SCSI_NO_
RESOURCE
SCSI task initialization
failed
Microcode 100%
2501 FSC_SCSI_BAD_
MESSAGE
SCSI task received a
bad message
Microcode 100%
2502 FSC_SCSI_QUEUE_FULL SCSI queue full Microcode 100%
2503 FSC_SCSI_NO_FAS366 FAS366 not detected Servo/SCSI 100%
2504 FSC_SCSI_INVALID_
PAGE_CODE
Bad page code in send
diagnostic
Host 100%
2600 FSC_SERVO_NO_
RESOURCE
SERVO task
initialization failed
Microcode 100%
2601 FSC_SERVO_QUEUE_
FULL
SERVO queue full Microcode 100%
2602 FSC_SERVO_X_AXIS_
NOT_IN_POSITION
The X axis failed to get
to its target position
2603 FSC_SERVO_Y_AXIS_
NOT_IN_POSITION
The Y axis failed to get
to its target position
2604 FSC_SERVO_THETA_
AXIS_NOT_IN_
POSITION
The THETA axis failed
to get to its target
position
2605 FSC_SERVO_PICKER_
AXIS_NOT_IN_
POSITION
The PICKER axis failed
to get to its target
position
2606 FSC_SERVO_SHUTTLE_
AXIS_NOT_IN_
POSITION
The Shuttle axis failed
to get to its target
position
FSC Name Description FRU Name Confidence %