Appendix B Fault Symptom Code (FSC) Dictionary
130 ATL M-Series User’s Guide
2637 FSC_SERVO_SHUTTLE_
PICKER_CALIBRATION_
ERROR
The shuttle is set too
far back on the Picker
axis
2638 FSC_SERVO_GROSS_
POSITION_ERROR
One of the axes has
suffered a gross
position error
2639 FSC_SERVO_SLOT_
CALIBRATION_ERROR
The cartridge position
error detected on the Y
axis is too great
263A FSC_SERVO_DRIVE_
FXD_SLOT_
CALIBRATION_ERROR
The cartridge position
error detected on the X
axis is too great
263B FSC_SERVO_
CLEANING_TAPE_
EXPIRED
The cleaning tape in
use has expired
263C FSC_SERVO_NOT_
CLEANING_TAPE
The auto-clean cycle
has loaded a non-
cleaning or invalid
tape
263D FSC_SERVO_SHUTTLE_
NOT_IN_POSITION
The shuttle has not
been detected opposite
the Picker during
calibration
263E FSC_SERVO_
CARTRIDGE_NOT_
FULLY_HOME_IN_
SHUTTLE
The cartridge is not
fully in the shuttle,
manual intervention
required
263F FSC_SERVO_
CARTRIDGE_NOT_
FULLY_HOME_IN_
DRIVE
The cartridge is not
fully in the drive,
manual intervention
and power cycle are
required
FSC Name Description FRU Name Confidence %