Chapter 5 Specifications
Environmental Requirements
52 LTO-5 Tape Drive User’s Guide
Environmental Requirements
Tab l e 8 lists the environmental specifications of the LTO-5 Half-Height
Tap e D r iv e .
Ta b l e 8 Environmental
Requirements
Track density 123.5 tracks per mm (3136 tracks
per inch)
Transfer rate (sustained) 140 Mbytes/second (max, native)
Specification Value
Specification Operational Nonoperational
Acoustic level idling
(A-wt sum)
52 dBA maximum 5.0 LwA Bels —
Acoustic level operational
(A-wt sum)
57 dBA maximum 5.5 LwA Bels —
Airflow requirements Internal: 9 CFM (front to back) N/A
Altitude max 10,000 feet MSL
(at 25°C)
40,000 feet (power off)
Humidity gradient 10% per hour 10% per hour
Relative humidity 20% to 80% non-condensing 10% to 95% non-condensing
Shock (1/2 sine wave) 10 Gs peak, 11 msec 40 Gs peak, 11 msec
Temperature +50° to +104°F
(+10° to + 40°C)
–40° to +149°F
(–40° to + 66°C)
Comentarios a estos manuales