19-18
SCSI REFERENCE 1014826
CHAPTER 19—REQUEST VOLUME ELEMENT ADDRESS (B5h)
19.3.8 ASC AND ASCQ VALUES FOR ABNORMAL STATES
Table 19-2 contains a list of the ASC and ASCQ values that appear in the
Additional Sense Code and Additional Sense Code Qualifier fields of an
element descriptor if the element is in an abnormal state. Table 19-2 also
indicates the corrective action for each abnormal state. The Except field of an
element descriptor indicates if the element is in an abnormal state.
19.4 COMMAND STATUS
The library returns a status byte after processing the REQUEST VOLUME
ELEMENT ADDRESS command. This section describes when each type of
status byte might be returned.
Table 19-2 ASC and ASCQ values for abnormal element conditions
ASC ASCQ Description Corrective Action
83h 00h Label
questionable
The bar code label is questionable. Issue an INITIALIZE ELEMENT
STATUS (07h or 37h) command to reread the label.
Replace the label. Refer to the Magnum 224, StorageLibrary T24,
or StorageLoader 2U LTO Library Product Manual or the Magnum
448 LTO Library Product Manual for information about placing the
labels on the cartridges. For specifications for the bar code labels
that can be used with the library, refer to the Tandberg Data Bar
Code Specification for LTO Ultrium Cartridges.
If the error persists, contact your service provider.
83h 01h Cannot read bar
code label
Replace the label. Refer to the Magnum 224, StorageLibrary T24,
or StorageLoader 2U LTO Library Product Manual or the Magnum
448 LTO Library Product Manual for information about placing the
labels on the cartridges. For specifications for the bar code labels
that can be used with the library, refer to the Tandberg Data Bar
Code Specification for LTO Ultrium Cartridges.
If the error persists and the label is properly placed, contact your
service provider.
83h 03h Label and full
status
questionable
The library was powered on or the cartridge access port door was
opened. The cartridge inventory may have been violated. Issue an
INITIALIZE ELEMENT STATUS (07h or 37h) command to
reestablish the cartridge inventory.
83h 09h No bar code
label
If the cartridge does not have a bar code label, place a label on
the cartridge. Refer to the Magnum 224, StorageLibrary T24, or
StorageLoader 2U LTO Library Product Manual or the Magnum 448
LTO Library Product Manual for information about placing the
labels on the cartridges. For specifications for the bar code labels
that can be used with the library, refer to the Tandberg Data Bar
Code Specification for LTO Ultrium Cartridges.
If error persists and a label is present and properly placed, contact
your service provider.