JULY 2007 MAGNUM 224, MAGNUM 448, STORAGELIBRARY T24, OR STORAGELOADER 2U
A-15
ERRORS REPORTED OVER THE SCSI BUS
04h 8Dh 21h 02h O 11, 2 Not Ready. Key mode. An application
tried to issue commands to the library
while it was being controlled from the
operator panel.
04h 8Eh 1Eh 02h O 11, 2 Not Ready. Sequential mode. An
application tried to issue commands to
the library while it was in Sequential
mode.
15h 81h 09h 4h T, L, D 8, 14,
12,13
Pick failure. The cartridge loader could
not pick a cartridge because of
mechanical problems.
15h 83h 09h 4h T, L, D 8, 14,
12,13
Put failure. The cartridge loader could not
place a cartridge because of mechanical
problems.
1Ah 00h 10h 5h A 4 Parameter length error. The parameter
list length was not valid. This error is a
result of any of the following:
Parameter List Length error in the
MODE SELECT CDB.
Illegal transfer length in CDB.
20h 00h 10h 5h A 4 Invalid Command OP code. The
operation code (OP code) for the CDB
was invalid.
21h 01h 10h 5h A, O 4 Invalid element address. There was an
invalid element address specified in the
CDB.
24h 00h 10h 5h A 4 Invalid field in CDB. There were invalid
fields in the CDB.
25h 00h 10h 5h A, O 4 Logical Unit not supported. The logical
unit number specified in the Identify
message or in the CDB is not zero.
26h 00h 10h 5h A, O 4 Invalid field in parameter list. There was
an invalid field in the parameter list.
26h 02h 10h 5h A, O 4, 15 Parameter value invalid. There was an
invalid parameter value in the parameter
list.
28h 00h 00h 6h I 10, 11 Not Ready to Ready. Door closed. The
library’s door was opened and then
closed.
Table A-3 REQUEST SENSE error information (ASC, ASCQ, FSC, and SK) (continued)
ASC
(byte 12)
ASCQ
(byte 13)
FSC
Sense
Key
Cause ERP SCSI Error Message and Description